PRESS RELEASES

Press Releases

>
>
Movendo and University of Miami launch collaboration to predict, assess and treat sports injuries in student-athletes.

Movendo and University of Miami launch collaboration to predict, assess and treat sports injuries in student-athletes.

26 - 04 - 2021

Boston, MA – April 26, 2021 – Movendo Technology has launched a collaboration with the University of Miami to integrate Movendo’s hunova© robotic system into the screening and physical rehabilitation of their student-athletes.

You may also be interested in:

Press Releases

Holy Name Becomes First Hospital in New Jersey To Offer Innovative Technology to Restore Balance

Movendo Technology

16 - 05 - 2022

Press Releases

Generali supports Movendo Technology to establish the first robotic Post Covid center in Munich within the Ludwig-Maximilian University facility

Movendo Technology

27 - 01 - 2022

Press Releases

Movendo and Maragal Medical partner to predict the fall risk of older adults with new robotic system and artificial intelligence

Movendo Technology

27 - 12 - 2021

Press Releases

Movendo and University of Miami launch collaboration to predict, assess and treat sports injuries in student-athletes.

Movendo Technology

26 - 04 - 2021

Press Releases

Smith+Nephew adds Movendo Technology’s patient rehabilitation solution to Real Intelligence digital ecosystem

Movendo Technology

25 - 03 - 2021

Press Releases

Generali develops cutting-edge solution in cooperation with Movendo for robot-assisted fall prevention

Movendo Technology

08 - 02 - 2021

Product technical data

  • Dimensions: 55 x 55 x 71 inches (140 x 140 x 180 cm)
  • Net weight: 441 lbs (200 Kg)
  • Maximum patient weight : 331 lbs (150 Kg)
  • Maximum input power:
    • 1400 VA (for SN>=190)
    • 2500 VA (for SN<=189)
  • Power supply voltage: 115/230 Vac.
  • Nominal frequency: 50/60 Hz.
  • Maximum angular speed: 180 °/s.
  • Maximum inclination of bipodalic platform in all directions: ±18°
  • Maximum inclination of monopodalic platform in ankle configuration (sitting):
    • Plantar flexion/extension: ±30°;
    • External flexion/extension: ±18°;
  • Maximum inclination of monopodalic platform in standing position:
    • Plantar flexion/extension: ±18°;
    • External flexion/extension: ±18°;
  • Maximum robotic seat inclination:
    • Sagittal plane: ±13°;
    • Frontal plane: ±13°
  • Maximum transmissible torque, seat and platform: 200 Nm.
  • Torso sensor battery APC0000500
    • Power supply voltage and capacity: 3,7 Vdc 1000mAh
  • Torso sensor battery AME0000004
    • Power supply voltage and capacity: 3,7 Vdc 1000mAh
  • Operating temperature: 50° F (10° C) to 86° F (30° C)
  • Storage temperature: 50° F (-20° C) to 86° F (70° C)
  • Ambient relative humidity: 30 to 75% non-condensing
  • Atmospheric pressure: No effect
  • Altitude: Maximum 6561 ft (2000 m)